房检了个百年老房,阁楼今年刚装修过。inspector 说这屋顶只有ridge vent不够排
气.我们把问题丢给了屋主,屋主找了之前的contract询问,他们的回复是用了比较新
的技术
The insulation was installed as required by code section 101.4.3 to an R-34
open cell (which is a full cavity in a 2X8)
The enclosed envelope is a very common practice in the building industry
which had been around for over 4 years. It is most commonly referred to as a
hot roof. The best example of a hot roof is a typical box retailer like
lowe’s. These buildings have 6-8” of foam on the flat roof deck.
Here is a link to a site for some better information.
http://www.greenbuildingadvisor.com/green-basics/vented-or-unve
我们在网上做了些research,也没找到太多异议,普遍看到反映比较节能。将问题继续
丢给inspector,希望他能确定一下。结果,他还是坚持自己的意见。这边这方面的专
业人才比较多,想听听大家的意见。
我们在的地区是半年冬天的美国东北部。
t*******6
发帖数: 215
2
有vent好,不vent比较容易出问题。

34
a

【在 e*****r 的大作中提到】
: 房检了个百年老房,阁楼今年刚装修过。inspector 说这屋顶只有ridge vent不够排
: 气.我们把问题丢给了屋主,屋主找了之前的contract询问,他们的回复是用了比较新
: 的技术
: The insulation was installed as required by code section 101.4.3 to an R-34
: open cell (which is a full cavity in a 2X8)
: The enclosed envelope is a very common practice in the building industry
: which had been around for over 4 years. It is most commonly referred to as a
: hot roof. The best example of a hot roof is a typical box retailer like
: lowe’s. These buildings have 6-8” of foam on the flat roof deck.
: Here is a link to a site for some better information.

e*****r
发帖数: 25
3
那在这个封闭的基础上还能再加VENT么?

【在 t*******6 的大作中提到】
: 有vent好,不vent比较容易出问题。
:
: 34
: a

s******s
发帖数: 2721
4
soffit vent + attic vent channel + ridge vent应该够了。。

34
a

【在 e*****r 的大作中提到】
: 房检了个百年老房,阁楼今年刚装修过。inspector 说这屋顶只有ridge vent不够排
: 气.我们把问题丢给了屋主,屋主找了之前的contract询问,他们的回复是用了比较新
: 的技术
: The insulation was installed as required by code section 101.4.3 to an R-34
: open cell (which is a full cavity in a 2X8)
: The enclosed envelope is a very common practice in the building industry
: which had been around for over 4 years. It is most commonly referred to as a
: hot roof. The best example of a hot roof is a typical box retailer like
: lowe’s. These buildings have 6-8” of foam on the flat roof deck.
: Here is a link to a site for some better information.

1 (共1页)
进入Living版参与讨论
相关主题
洗澡间的风扇没有管道接通到屋顶外面soffit vent and ridge vent
attic clean up insulation大概多少钱?Attic上的风扇问题
阁楼天花板因为condensed水长霉,怎么办?装attic fan可能会使屋顶漏?(有ridge vent)
Urgent- mold in attic, please help!感觉装了attic fan对顶层温度降低还是很有帮助的
attic用close cell foam insulate了是不是就不用vent了?紧急求救,upper attic上有mold
spray foam insulation 能不能买?美国北方地区应该安装什么样的Attic Fan极其控制器?
问个roof venting的问题谁给推荐attic fan
请Home energy audits检查roof ventilation靠谱吗?屋顶的风扇
相关话题的讨论汇总
话题: foam话题: 房检话题: attic话题: vent话题: roof