由买买提看人间百态

topics

全部话题 - 话题: hspf
1 (共1页)
R*****8
发帖数: 4
1
来自主题: Environmental版 - HSPF or related watershed modeler position
一个小公司可能会找 full time or part time HSPF or related watershed modeler,
有兴趣的可以站内联系。 或者发 CV 给我。
R*****8
发帖数: 4
2
来自主题: Environmental版 - HSPF or related watershed modeler position
一个小公司可能会找 full time or part time HSPF or related watershed modeler,
有兴趣的可以站内联系。 或者发 CV 给我。
i***e
发帖数: 9429
3
来自主题: Living版 - 解答空调

For York Affinity 16 SEER, 9.0 HSPF Heat Pump
Efficiency for 2 Ton Model #: YZF02413C
1)with York Affinity Air Hander AVG36C (21" wide)
系统效率: SEER 16 HSPF 9.0
这台Air Handler 估计你无法装 , 是21寸宽度的,如果位置够可以装的话,那将是非
常好,是York 顶级Affinity系列。
估计是给你下面的型号。
2)with York LX Series Air Hander AHE24B (17.5"wide)
系统效率: SEER 15 HSPF 8.5
这台是17.5寸宽度, 出风量在800CFM左右。
3) with York LX Series Air Hander AHE30B (17.5"wide)
系统效率: SEER 15 HSPF 8.5
这台也是17.5寸宽度, 出风量在1000CFM左右。
... 阅读全帖
i***e
发帖数: 9429
4
来自主题: Living版 - 电还是Gas空调?

了。
很感谢, heat pumps 的效率 和Geothermal Heat Pumps 当然没法比,说到
Geothermal Heat Pumps,有一点我倒不是很确定,在open loop 状态下,COP值再怎么
算,效率最高也不过在500%-600%, 但Heat pump 机子是根本达不到这个效率的,可
tend 在三楼提到在那个温度点heat pump最高可达到500%,我是想不出他是用哪一个品
牌,多少吨位的机子做如何的计算得出来的,或许我哪里没有想到? HSPF 10的机子,
达到300% 是完全可能的,可是要知道驾Mercedes 的毕竟是少数, 房奴们怎么买得起啊
!如果真的需要装到如此豪华的机子组合也能节省能源,这岂不是和穷人开玩笑。
15 SEER heat pump 一线,二线机子也就3,4个厂家在制造,且都是品牌厂家, HSPF 值
都可达到或超过9,配对好的话可达到9.2,去年有个机会对其中一个品牌的3顿 14
SEER,HSPF 8.5机子在37F的环境下做过计算,当时计算出的效率值在220% 左右。这儿
的气温已上升到50F,不然的话我到是很有兴... 阅读全帖
c****e
发帖数: 749
5
来自主题: Living版 - 电还是Gas空调?
首先看供暖性能要看HSPF. SEER是指对供冷来说的。虽然SEER越高HSPF也会越高,但同
等SEER或相近时,就不好说了。 所以用HSPF才是正解。
其次,所谓的效率高低,只能是热泵和热泵比(电和电),天然气和天然气比,用电的
和烧气儿的之间没法比较效率。不是一码事儿。
只有安装,运行的费用可以进行比较。运行费用上要依据居住地的气候及电气价格而定
。如果在北部极寒地区,还是烧气为好。
另外几点要考虑:如果你的地区老停电,最好用气。另外现在电台整天说美国天然气储
量创历史记录啥的,没准气的价格会比电便宜(纯属本人瞎猜)。
再有考虑是今后的维护。现在的热泵用R-410A.十几年以后会不会被禁,就像现在的R22
那样,谁都不好说,一旦被禁,维修费用可能会涨。
i***e
发帖数: 9429
6
来自主题: Living版 - 电还是Gas空调?
想和chuyue 交流一下,就你提出的用HSPF 指数才是正解, 也就说将来的系统只要
HSPF 选择正确,Heat pump 系统是值得推广的,如果是,对于一般的家庭,从机子的
性价比和能源的节省去考量,你认为HSPF 指数 从7.7 到10 之间要保持在哪一个数值
是属于比较理想的。谢谢。
n******m
发帖数: 1551
7
来自主题: Living版 - 安装heat pump,请教imore
二楼的heat pump漏氟,而且已经17年了,这次不想再修了,直接换新的。请了Lennox
的dealer来做评估,给了三个options。请教imore, 哪种option的效率能够发挥的更好
些?型号信息如下:
option 1:
outdoor _ model XP21-024, 2 ton, 18.7 SEER/13.2 EER/9 HSPF
indoor_model CBX40UHV-024
Option 2:
Outdoor_ model XP17-024, 2 ton, 17.2 SEER/14.2 EER/9.5 HSPF
indoor_model CBX40UHV-024
For option 1& 2, will install a new Lennox Wi-Fi communicating control
mounted in the same location as the existing thermostat.
Option 3:
Outdoor_ model XP14-024, 2 ton, 16.2 SEER/13.7 EER/9 HSPF
indo... 阅读全帖
s****s
发帖数: 368
8
来自主题: Living版 - 安装HVAC
打算装新的HVAC,招了三家来估价,有一家是$4995:
We propose to furnish all labor, material and equipment to install Quality
Heating & Cooling Systems Using Carrier Cooling & Heating Equipment in
accordance with the following conditions and specifications:
Equipment: 15 SEER 12.5 EER 8.7 HSPF
1 Carrier 25HCC542A003/ 3.5-Ton Comfort 15 Series Puron Heat Pump
1 Carrier FX4DNF043T00 Comfort Series Speed Fan Coil
1 Carrier KFCEH3001F15 15-KW Electric Heater Package
1 Carrier TC-PHP Comfort Series Programmable Thermost... 阅读全帖
t***s
发帖数: 4666
9
来自主题: Living版 - 用电和用Gas哪个省钱
衡量air sourced heat pump的效率是用HSPF,SEER是衡量cooling A/C的。HSPF 8.5
以上才qualify去年的tax credit,相当于全年平均的COP 250%。

performance
43
a
is
c******n
发帖数: 381
10
来自主题: Living版 - 解答空调
楼主你好,马上要换空调,预算是经济型的,得到下面的估价,对不同的牌子和model
我们看了网上的评论,比如Carrier comfort 15和 comfort 13 比起来的噪音低些,省
电些。其他的区别我们不太理解.
旧的空调是YORK ,3.5 Ton Heat Pump。 家里面积一楼1300,二楼五百多。
问题:
1)下面不同的机子关键区别在哪儿,区别大吗?哪一种性价比比较好?
特别是Carrier comfort 15和 comfort 13 的比较。
2)当地还有一家代理Tempstar 这个牌子的,quote要明天才有。网上评论是他家的高
端机子T开头的 model 质量还不错,可以和Carrier比较。这个牌子如何?
谢谢你的建议。
Warranty: Ten Years Parts, Five Years Labor
1)Total Cost: $5,854
Carrier Comfort 15 High Efficiency Heat Pump & Comfort Series Air Handler
Carrier Comfort 15, 25HBC5... 阅读全帖
c******n
发帖数: 381
11
来自主题: Living版 - 解答空调
楼主你好,马上要换空调,预算是经济型的,得到下面的估价,对不同的牌子和model
我们看了网上的评论,比如Carrier comfort 15和 comfort 13 比起来的噪音低些,省
电些。其他的区别我们不太理解.
旧的空调是YORK ,3.5 Ton Heat Pump。 家里面积一楼1300,二楼五百多。
问题:
1)下面不同的机子关键区别在哪儿,区别大吗?哪一种性价比比较好?
特别是Carrier comfort 15和 comfort 13 的比较。
2)当地还有一家代理Tempstar 这个牌子的,quote要明天才有。网上评论是他家的高
端机子T开头的 model 质量还不错,可以和Carrier比较。这个牌子如何?
谢谢你的建议。
Warranty: Ten Years Parts, Five Years Labor
1)Total Cost: $5,854
Carrier Comfort 15 High Efficiency Heat Pump & Comfort Series Air Handler
Carrier Comfort 15, 25HBC5... 阅读全帖
i***e
发帖数: 9429
12

Gas
Gas
取暖可以用中央空调,另外有Gas取暖器。刚搬进去个把月,还不需要取暖,所以Gas
一直没有开通。那么我取暖是用Gas还是空调好?当然是哪个选择省钱?
如果我的理解正确的话,楼主的可能是dual fuel type。 如果真是dual fuel 系统,
曾经是有过一个贴的。当时有个id 用了亲身体验的轨迹计算,得出的结果是当室外温
度降到40度左右(具体值记不清了), 是需要用到gas furnace 的,当时我提出的是机
子的效率越高,不需要在40F 切换。在几个来回中,我记得chuyue 把HSPF 这词带入
了论坛,以比较客观的见解来讨论机子在低温下的运行依据,我记得当时是围绕着某一
品牌的某一个型号。楼主的地理位置是肯定需要用到gas furnace 的,但是用到的频率
并不一定很长,再根据你目前的一些情况,如室内空间面积,gas 除了取暖,没再用其
它的,整年计算每月gas 帐单必须付的基本费用,虽然在冬季的某一个月在单暖气使用
上电的费用会告过gas,但是一整年的花费上如果做个比较的话,单用电取暖的话也不
是不可行的, 具体还得看你目前机子的 系统HSPF... 阅读全帖
i***e
发帖数: 9429
13
来自主题: Living版 - 空调比较,紧急求助!

13ACX-30 是 A/C only, 不是 heat pump, 应该是13HPX-030 + CX34-31 with TXV
SEER值: 13, HSPF值: 8
建议用XB13 + TRANE cased coil.
4TWB3030C1 + 4TXCB004
SEER值: 13.5, HSPF值: 8.2
x**i
发帖数: 113
14
Some efficient model has HSPF as high as 13.5 , much higher than my existing
heat pump ( hspf of 8 or 9 ).
So is it worth it to have one installed? those mini-split seems have pretty
good efficiency event at lower temp like 15 F.
有用过的人来讲一讲?
i***e
发帖数: 9429
15
来自主题: Living版 - 大神们了解Ruud这个牌子吗?
昨晚已看到你的贴,那时网络出了点问题。
这台heat pump 就是最基本的13 SEER 机子,HSPF 7.7 觉得低了点,不过还行吧,
fan coil 是不错的,ECM blower.
搭配后可达 SEER14.5, HSPF 8.5, 蛮好的。
去多比较两家,价位有下降空间的。
american standard 的机子在同级别上要比这个贵。
s********n
发帖数: 154
16
来自主题: Environmental版 - Anyone knows where I can download MAGIC model?
I know Mike She is a software developed by a Denmark company. I have ever
used it to simulate hydrology, but not water quality. Do you have any
experience of that software for the application in the watershed
ACIDIFICATION?
I also used HSPF from BASIN 4.0. HSPF runs good for nitrogen, but not pH due
to the program limitation. That's why I am looking for new model or
software to compute the acidification.
a***h
发帖数: 1222
17
来自主题: Environmental版 - Anyone knows where I can download MAGIC model?
The HSPF in BASIN model is a old version. It may not have the capacity of
simulating acid deposition. Also, HSPF is for surface water only. It can not
simulate groundwater transport.

due
G*****r
发帖数: 369
18
来自主题: Living版 - 请教换中央空调的事宜。
http://www.nytimes.com/gwire/2010/03/08/08greenwire-democrats-to-turn-spotlight-on-energy-efficien-54735.html
summary:
50%, =<3,000, All rebates would be provided instantly at the retail store.
Air-conditioner or heat-pump replacement with a new unit that—
(A) is installed in accordance with ANSI/ACCA Standard 5 QI–2007; and
(B) meets or exceeds—
(i) in the case of an air conditioner, SEER 16 and EER 13; and
(ii) in the case of a heat pump, SEER 15 and EER 12.5 and HSPF 8.5.
看来这个bill过了还是换不起全套。为啥
i***e
发帖数: 9429
19
来自主题: Living版 - 解答空调

HEPA的空气净化过滤系统 要把型号贴上来。
不管用那个Fan Coil, 系统效率都一样。
EER: 11
SEER: 13
HSPF: 7.7
5ton 的机子别指望效率会达到预期的。
如果是同一个型号,1.5ton. 2ton, 2.5ton, 3ton 一般都行的。
s*****d
发帖数: 469
20
来自主题: Living版 - 安装heat pump,请教imore
那只要比较SEER/EER/HSPF就可以了,至于什么WIFI,2-STAGE,变频啥的就免了吧.
i***e
发帖数: 9429
21
来自主题: Living版 - heat pump furnace有啥优缺点
你那地区建议你装15 SEER或16SEER,HSPF 高于9.0 的热泵 + variable speed furnace。
总体费用比同等级 AC + gas furnace 贵出1500刀-2000刀
不差钱的话上dual fuel系统
i***e
发帖数: 9429
22
来自主题: Living版 - 大神们了解Ruud这个牌子吗?
A.S 组合得到的效率没有RUUN好。不过呢这个机子整体工艺要比RUUD好,
EE R11.5, RUUD是12
SEER14, RUUD是14.5
HSPF 都一样
air handler 比RUUD 安静。
如果是我的话,我会选american standard. 不过我是imore,你是keylock,是两个完全
不同的ID,我喜欢的不一定你喜欢,你喜欢的不一定我愿意,你懂的。
4A6H4030D1 TEM4A0B30S31+TDR 950 28200 11.50 14.00 28000 8.50 18200
i***e
发帖数: 9429
23
来自主题: Living版 - 大神们了解Ruud这个牌子吗?
cooling capacity 28800 btuh
EER 12.00
SEER 14.50
Heating capacity @ 47F 28400 btuh
Heating capacity @ 17F 17000 btuh
HSPF 8.20
d**e
发帖数: 13
24
来自主题: Living版 - 换空调,请大拿们帮看看报价
麻烦大拿帮看看这两个报价选哪个好些,我们在 TX, 2200 sqt, ranch, 两个都是
local 小公司,口碑都还不错:
公司 1: ASZC160481 Amana 4 ton 2-stage 16 SEER 9.20 HSPF rated R-410A heat
pump condensing unit.
indoor unit 似乎都是 Goodman 的零件组起来的,包括(
CHPF4860D6 horizontal evaporator fan coil. (suspend from rafters)
TX5N4 TXV
MBVC2000AA-1 variable speed blower unit. (suspend from rafters))
还有些 其他附加的: HKA-20 20 KW back up heat.
composite AC pad on existing concrete, level with rubber isolator
10 parts and year labor w... 阅读全帖
i***e
发帖数: 9429
25
来自主题: Living版 - 换空调,请大拿们帮看看报价
我刚才没查到,现在查到了。
Amana的组合要比lennox 组合效率高一点,尤其是HSPF值,还有就是Amana 是Goodman
的高端品牌。另外这套系统全部是ComfortNet Compatible。 要师傅给你装个
ComfortNet Communicating Control(温控器),最后要提醒的是室外温度很高的话,
空调很有可能一直在运行(single stage),或运行周期很频繁,有的人是很喜欢这样子。
Lennox 也是很不错的。
我常会说如果是我的话我会选。。。, 不过你这两个很难选。
Active Systems AMANA ASZC16 AMANA HEATING AND AIR CONDITIONING ASZC160481A*
CHPF4860D6D*+MBVC2000**-1A*+TXV 1550 1100 47500 12.50 16.00 47000 9.20
34000
Active Systems ELITE XP16 SERIES LENNOX INDUSTRIES, INC. XP16-048-230-08
CBX32M-... 阅读全帖
d**e
发帖数: 13
26
来自主题: Living版 - 换空调,请大拿们帮看看报价

Goodman
子。
*
20
谢谢 imore, 你确实也说到了我想到的点,就是lennox 那个的HSPF 有点低, Amana 的
师傅报价中包括给装个 Honeywell Pro 9000 Wi-Fi thermostat。 这两个报价有点难
选,所以才想听听各位的意见,两个师傅经验都挺丰富,就剩下有些 小细节差别了,
lennox 的师傅 要给室外那个 unit 下面用 concrete slab, amana 那个师傅 用
composite AC pad 和 rubber isolators. 看review, Lennox 那家装整机的似乎比较
多,都是自己的人,amana 这家比较新,开了 4年,他家的安装是雇外面的团队,但是
短时间呢,口碑攒的不错。部件上,Amana 那个 air handler 是 Variable Speed,
lennox 应该不是。 这两个确实很难选啊,imore 有没有更偏向哪个啊?
d**e
发帖数: 13
27
来自主题: Living版 - 换空调,请大拿们帮看看报价

Qianshuiba, 不好意思, 把回复不小心点成回信了,请忽略回信。
Amana 的 coil 从 tube 到 fin 都是 aluminum, Lennox 还是 copper tube +
Aluminum fin. Lennox 的师傅可以把 air handler 给换成 HSPF 9.5的 CBX32MV-060
variable speed air handler, 但是要加 $1500.00
相比同样性能 Amana 的价格还稍微低些,决定从了Amana
d**e
发帖数: 13
28
来自主题: Living版 - 换空调,请大拿们帮看看报价

是。
谢谢 imore, Lennox 的师傅强调如果我们要 HSPF高的话,就一定要装 CBX32MV-60,
还要 多加1500,说是不能再少了, 这个变速 的air handler 是 5TON,这样就变成 室
外 4ton, 室内5ton,而且我家是 40A breaker, 5ton 的话,估计负荷太重。 我们决定
还是从了 Amana, 这些配置都还可以,主要是安装,安装也是影响机器lief time 和
performance 的关键因素
i***e
发帖数: 9429
29
来自主题: Living版 - 用电的空调换成用GAS 的成本?
外机如果较新的话不用换, 內机换了就行。
Gas Furnace + Cased Coil,这样未来就是dual fuel 系统,特省运行成本, 当室外
温度高于45F 时, 开暖气用的是heat pump, 室外温度低于45F 时,开暖气用的是gas
furnace.
根据你目前外机的HSPF值,值越高的话,有些高端机子在室外温度低于20F时亦可运行
Heat pump。
i***e
发帖数: 9429
30
来自主题: Living版 - 用电的空调换成用GAS 的成本?
外机如果较新的话不用换, 內机换了就行。
Gas Furnace + Cased Coil,这样未来就是dual fuel 系统,特省运行成本, 当室外
温度高于45F 时, 开暖气用的是heat pump, 室外温度低于45F 时,开暖气用的是gas
furnace.
根据你目前外机的HSPF值,值越高的话,有些高端机子在室外温度低于20F时亦可运行
Heat pump。
i***e
发帖数: 9429
31
来自主题: Living版 - 空调加热失败的一个猜想
室外温度在32F(0C)时,需要用到HSPF 9.5的热泵才会给力,出风口的温度应该要在
90-100F左右。室外低于32F时, 自动切换到电热丝或gas furnace.
f******a
发帖数: 148
32
来自主题: Boston版 - 推荐个电工?
除了SEER,还要看EER和HSPF.
去年的tax credit和今年的coolsmart $500 rebate是这三个指标都要看的。
分体其实是EER这个指标最难达到。
而且分体你不同的室内和室外机的搭配,实际效率指标也是不一样的。
s********n
发帖数: 154
33
来自主题: Environmental版 - Anyone knows where I can download MAGIC model?
酸雨最主要的影响应该在land上,从我们测定的soil水样中看出来浅层的已经有比较明
显的酸化,深层的影响还比较小。从河流的测定上来看,下雨对河流的pH影响很大,但
baseflow可以把pH逐渐调上来,现在河流的pH在5.5~6.5之间。
我们手上有15年的15分钟在线监测的流量,pH和碱度的数据,另外还有biweekly的沉降
和河流水质的数据。所以从数据方面来说,虽然不是十全十美,但还是比较可以的。
本来我的课题计划是分为三步,第一步是先做个模型来了解一下该区域在酸雨沉降后可
能发生的反应或者过程,来确定一些重要参数,从而达到预测和控制的目的。然后在模
型的基础上再通过现场或者柱状实验对一些参数进行验证或者改正,进一步确认模型的
准确性。第三步将基于第二步的结果再决定。
现在用HSPF模拟了之后觉得很不理想,而且这个所谓的模型还是在一个合同上的,所以
想糊弄过去也比较难,现在我就是处在这么一个尴尬的位置。哎。。。。
不管怎样,真的很感谢楼上各位的回复,你们给了我很多信息。难得看到这里有个帖子
居然有这么多回复,呵呵:)
a***h
发帖数: 1222
34
来自主题: Environmental版 - Anyone knows where I can download MAGIC model?
嗯,花些时间应该可以做些很不错的结果。
有个问题,您们15分钟的检测结果,在降雨期间,pH上升还是下降?我做过的一个酸雨
项目,监测数据表明pH在降雨期间出现波峰。
HSPF不具备化学反应模拟能力,必须要和其他化学反应模型结合才能模拟pH。
w****a
发帖数: 1623
35
来自主题: Environmental版 - Anyone knows where I can download MAGIC model?
You can add Minteq algorithm in HSPF.
p*******o
发帖数: 5
36
来自主题: Environmental版 - HSPF or related watershed modeler position
请问现在还需要人吗,我是做watershed modelling的
1 (共1页)